Характеристики:
Fan for drying: Voltage 220/240 V (min.) | 220 V |
Water pressure: Inlet pressure | 0.3 bar - 10 bar |
Rotations: Drain pump motor | 3000 RPM |
Detergent capacity: Rinse aid dosage | 135 cm 3 |
Electronic boards: Serial boards (Data set) | 481814 |
Regeneration with automatic salt adaption: after wash cycles | Depending on the water hardness |
Flow rates/ Inlet volume: Shower/Spray arm top | ~ 8 l/min |
Spray pump motor: Voltage | 220/240 V |
Heating element: Temperature on surface | ~ 115 °C |
Flow rates/ Inlet volume: Fan for drying | Total 900 l/min Primary air flow 210 l/min Secondary air flow 780 l/min |
Spray pump motor: HA | 60 Ω |
Detergent capacity: Prewash | 10 cm 3 |
Drain pump motor: Power Consumption | 30 W |
Coil of dispenser: Resistance | 1.3 k Ω |
Flow rates/ Inlet volume: Spray pump | 45 l/min - 65 l/min |
Program information: | All programs will be locked after start. Changing the program or ?nishing the program will be possible only after pressing the start button for longer then 1.5 sec. (Break by customer) A switching off the appliance or unplug the appliance for a while, this will frozen the program step and later on, the program continuos on the same position. Exception: Switching off the appliance or unplug the appliance during the drying phase, this will lead directly to the end of the program. |
Spray arms, turning rhythm at alternating spray system: Intermediate rinse | Spray arm lower ~2min Upper arm ~2min Spray arm upper ~ 2 min |
Электрические базовые данные: напряжение | 220/ 230 V |
Spray pump motor alternating spray system: Capacitor | 4 µ F |
Heating element: Safety thermostat self reset (Temperature of water) | ~ 85 °C |
Rotations: Spray pump motor | 2800 RPM |
Motor Diverter Valve: Signal (2x within ~13 sec.) | 5.0 V |
Water hardness: water hardness | 0 - 60 °dh 0 - 10.7 mmol/l 0 - 107 °Fh |
Heating element: | 1 Element system |
Electronic boards: Serial boards (Basic UCB, not programmed) | 4619 724 60492 |
Single electric water inlet valve: Resistance | 3.76 k Ω |
Data Energy Label: Drying Performance | A |
Single electric water inlet valve: Voltage | 220/ 240 V |
Heating element: Power Consumption | 1.87/ 2.04 kW |
Regeneration valve: Frequency | 50/ 60 Hz |
Rotations: Spray arm upper | 30 RPM - 40 RPM |
Regeneration with automatic salt adaption: Volume | 300 cm 3 |
Flow rates/ Inlet volume: Pump height max. | 1.1 m |
Flow rates/ Inlet volume: Spray arm lower | ~ 33 l/min |
Water softener: Resin container | 900 cm 3 |
Motor Diverter Valve: Voltage | 220 V - 240 V |
Electronic boards: Serial boards (LCD) | Display 1 4619 724 96801 |
Heating element: Voltage | 220/ 230 V |
Flow rates/ Inlet volume: Inlet valve | 4 l/min |
Accessory: | If you need spare parts apart from the spare part list have a look in the Service Bulletin 4812 718 40084. |
Fan for drying: Voltage 220/240 V (max.) | 240 V |
Water softener: Salt container | 2 kg |
Spray pump motor: HI | 79 Ω |
Alarms: Refill salt | Wasserhahn geschlossen |
Spray pump motor: Capacitor | 4 µ F |
Options: | Zone washing Delay function Sani rinse program |
Electronic boards: Serial boards (CB programmed) | 481824 |
Dimensions + Weight: Product dimensions () | Free standing appliances with flat/ square outer door |
Drain pump motor: Voltage | 220/ 240 V |
Spray arms, turning rhythm at alternating spray system: Final rinse | Spray arm lower ~2min Upper arm ~2min Spray arm upper ~ 2 min |
Detergent capacity: Dosage steps | 1 ml - 6 ml |
Electrical base data: Total power | 2.0 kW - 2.2 kW |
Regeneration with automatic salt adaption: Salt consumption for regeneration | 77 g |
Coil of dispenser: Frequency | 50/ 60 Hz |
Spray pump motor alternating spray system: Power Consumption | 125 W |
Dimensions + Weight: Product dimensions (Weight) | 58 kg |
Optical water indicator (OWI): Combination part of | Turbidity sensor (DON) Thermostat temp. sensor (notice NTC) |
Flow rates/ Inlet volume: Spray arm upper | ~ 27 l/min |
Heating element: Fuse | 206 °C |
Motor Diverter Valve: Frequency | 50/ 60 Hz |
Regeneration valve: Resistance | 3.13 k Ω |
Electronic boards: Serial boards () | Programing of version and programmed control board, see "Service" and "Data set" on rating plate of inner door: |
Regeneration with automatic salt adaption: Water hardness | 0 - 60 °dh 0 - 10,7 mmol/l 0 - 107 °Fh |
Data Energy Label: Energy Performance | A |
Flow rates/ Inlet volume: Flow meter | 208 lmp/l |
Data Energy Label: Reference program | A5a |
Размеры + Вес: Размеры продукта (ширина) | 59.7 cm |
Drain pump motor: Resistance | 146 Ω |
Succession of programs: Programs () | see program diagram |
Spray pump motor alternating spray system: HI | 79 Ω |
Электрические базовые данные: частота | 50 Hz |
Электрические базовые данные: Потребляемая мощность | 2,0 kW - 2,2 kW |
Spray arms, turning rhythm at alternating spray system: Prewash | Spray arm lower ~3min Upper arm ~1min Spray arm upper ~ 1 min |
Coil of dispenser: Voltage | 220/ 240 V |
NTC | 20 °C 58.1 kΩ 25 °C 47.1 kΩ 30 °C 38.2 kΩ 40 °C 25.4 kΩ 50 °C 17.2 kΩ 60 °C 11.8 kΩ 70 °C 8.3 kΩ 80 °C 6 kΩ 85 °C 4 kΩ 20 °C 58,1 kΩ 25 °C 47,1 kΩ 30 °C 38,2 kΩ 40 °C 25,4 kΩ 50 °C 17,2 kΩ 60 °C 11,8 kΩ 70 °C 8,3 kΩ 80 °C 6 kΩ 85 °C 4 kΩ |
Электрическая база данных: Предохранитель | 10 A |
Spray pump motor alternating spray system: Voltage | 220/ 240 V |
Water pressure: Spray pump pressure | 0.3 bar |
Размеры + Вес: Размеры продукта (Глубина) | 59.6 cm |
Spray arms, turning rhythm at alternating spray system: | Bemerkung: Nach Programmunterbrechungen im Testprogramm rotieren die Sprüharme wieder im Rhytmus des Hauptspülens (5/3 min). Wichtig: Zum Beenden des Testprogramms Startknopf länger als 1,5 s drücken. Nach Beendigung des Testprogramms (LED Ende an und/oder LED Start aus) muß das Gerät ausgeschaltet werden, andernfalls rotieren die Sprüharme beim nächsten Spülen weiter im Rhytmus des Testprogramms (30/30 s). |
Spray arms, turning rhythm at alternating spray system: Service Test program | Remark: When switching of the main switch or interrupt the mains during the Test Program runs, then the alternating of the spray arms change in the test program to the rhythm of main wash 5/3 min. After finishing the test program (End LED shines and/or Start LED goes of) must the appliance be switched off. Spray arm lower ~30sec Upper arm ~30sec Spray arm upper ~ 30 s |
Regeneration valve: Voltage | 220/ 240 V |
Rotations: Fan for drying | 2500 RPM |
Detergent capacity: Main wash | 40 cm 3 |
Spray arms, turning rhythm at alternating spray system: Main wash | Spray arm lower ~3min Upper arm ~5min Spray arm upper ~ 5 min |
Regeneration with automatic salt adaption: Number of cycles with 2 kg salt | 26 |
Water softener: Regeneration dosage | 300 cm 3 |
Heating element: Resistance | 24.5 Ω |
Water Volume: Water Volume Level | Regeneration 0.3 l 15 mm Back rinse 3x 1.0 l 60 mm Prewash 3.9 l 120 mm Main wash 3.2 l 118 mm Intermediate rinse 1 3.2 l 118 mm Intermediate rinse 2 3.2 l 118 mm Clear rinse 3.2 l 118 mm Safety/ overflow 8.5 l 141 mm Regenerieren 0,3 l 15 mm Rückspülen 3x 1,0 l 60 mm Vorspülen 3,9 l 116 mm Hauptspülen 3,2 l 112 mm Zwischenspülen 1 3,2 l 112 mm Zwischenspülen 2 3,2 l 112 mm Klarspülen 3,2 l 112 mm Sicherheitsniveau 8,5 l 141 mm |
Single electric water inlet valve: Frequency | 50/ 60 Hz |
Spray pump motor: Power Consumption | 125 W |
Heating element: Heating speed | ~ 2.0 °C/min |
Rotations: Spray arm lower | 30 RPM - 40 RPM |
Spray pump motor alternating spray system: HA | 60 Ω |
Data Energy Label: Cleaning Performance | A |
Flow rates/ Inlet volume: Drain pump | 16 l/min |
Размеры + Вес: Размеры продукта (Высота) | 85.0 cm |
Motor Diverter Valve: Resistance | 6.5 k Ω |